station.site WebMCP audit

Rescan
audited Nov 18, 2026in 11s
90/ 100100% of the applicable check weight evaluated

2 tools registered. Strongest in shared experience, weakest in tool selection.

Shared experience100
Tool selection66
Tool quality96
Trust100
https://station.site
Captured view of https://station.site

Tools

2 read, 0 write
Loading map
station_search_documentation: warning

station_search_documentation

Search Station's public API reference, MCP setup and guides when you need connection or collaboration instructions. Returns matching page paths, titles, original URLs and excerpts; read a match with station_read_documentation.Answers a question. Declared read only.

page

https://station.site/

implementation

viaimperative
entry pointdocument
registered after514ms
executepresent

api surface

queryrequired
limitoptional

annotations

read onlytrue
untrusted contenttrue
titlenot declared
consequentialfalse

1 finding

warningNaming quality
weight 2
Tool naming makes selection harder than it needs to be: 2 names do not start with a verb (station_search_documentation).
fix
{ name: "station_search_documentation" /* short, unique, verb-based */ }
tool JSON
{
  "name": "station_search_documentation",
  "description": "Search Station's public API reference, MCP setup and guides when you need connection or collaboration instructions. Returns matching page paths, titles, original URLs and excerpts; read a match with station_read_documentation.",
  "inputSchema": {
    "type": "object",
    "properties": {
      "query": {
        "type": "string",
        "minLength": 1,
        "maxLength": 200,
        "description": "Words to find in the public documentation, such as API authentication."
      },
      "limit": {
        "type": "integer",
        "minimum": 1,
        "maximum": 10,
        "default": 5,
        "description": "The largest number of matching pages to return."
      }
    },
    "required": [
      "query"
    ],
    "additionalProperties": false
  },
  "annotations": {
    "readOnlyHint": true,
    "untrustedContentHint": true,
    "consequentialHint": false
  }
}
Showing station_search_documentation

Findings

Shared experience

100 / 100 · weight 30
not applicableVisible effect
weight 6
Not invoked on this run: this audit did not call any tool. Scheduled re-audits only read the registry; a live audit from the report page calls the tools that declare readOnlyHint: true and not consequentialHint: true.
passPage experience
weight 16
The page a person sees holds up next to the agent surface: a working interface, visible actions, readable content, nothing in the way.
passHuman parity
weight 8
The person co-browsing can see and use this page - the same page the agent's tools act on.

Tool selection

66 / 100 · weight 25
not applicableInvoke success rate
weight 6
Not invoked on this run: this audit did not call any tool. Scheduled re-audits only read the registry; a live audit from the report page calls the tools that declare readOnlyHint: true and not consequentialHint: true.
warningTool selection
weight 12
An agent chose an existing tool and built a schema-valid call that held up on 2 of 3 canonical intents; on "What other pages are in the same section?" no tool on the page served it. Nothing was executed, so this verifies selection, not outcomes.
warningCoverage vs. site type
weight 7
The tool set covers 2 of the 3 things an agent needs on a docs site; it cannot navigate the documentation tree.

Tool quality

96 / 100 · weight 25
passRegistration timing
weight 1
Every measured tool registered within 514ms of navigation.
toolstation_read_documentation
passCanonical entry point
weight 3
All 2 tools register on the canonical document.modelContext entry point.
passSchema validity
weight 4
All 2 declared input schemas are structurally valid object schemas.
passSchema quality
weight 4
All 2 tool schemas describe their parameters, and every description stays within Chrome's size guidance.
warningNaming quality
weight 2
Tool naming makes selection harder than it needs to be: 2 names do not start with a verb (station_search_documentation).
toolstation_search_documentation
fix
{ name: "station_search_documentation" /* short, unique, verb-based */ }
passStub detection
weight 4
All 2 tools declare an execute handler.
passRegistration errors
weight 2
No tool registration threw during the capture.
passDescription quality
weight 5
All 2 rated tool descriptions say what the tool does, when to use it, and what it returns.

Trust

100 / 100 · weight 20
not applicableAnnotations present
weight 4
No tool name reads like a read, and an absent readOnlyHint already defaults to "this may write" - readOnlyHint: true is the hint this check scores, and this set has no read tool to declare it on. (On a write that is significant or hard to undo, consequentialHint: true tells the agent to confirm with the person first.)
passAnnotation mismatch
weight 4
No tool claims to be read-only while its own name or description says it writes (2 declared hints checked).
not applicableUntrusted content hint
weight 3
No tool's contract suggests it returns text written by somebody other than the site, so there is nothing to flag as untrusted.
not applicableConsequential hint
weight 3
No tool name reads like a consequential action (a purchase, a booking, a payment, a transfer, a deletion), so there is no consequentialHint to expect.
not applicableHint vs. observed
weight 3
Not invoked on this run: this audit did not call any tool. Scheduled re-audits only read the registry; a live audit from the report page calls the tools that declare readOnlyHint: true and not consequentialHint: true.
not applicableInjection surface
weight 3
No tool's metadata carries instruction-shaped text aimed at the agent reading it. This check only ever flags; it never credits a site.

Tool selection

67% across 3 intents
Find the page that explains authentication.ok
chosestation_search_documentationexpected docs searchkind matched
arguments
{
  "query": "authentication"
}
Read that page to me.ok
chosestation_read_documentationexpected page readkind matched
arguments
{
  "path": "/api"
}
What other pages are in the same section?missed
choseno toolexpected navigationkind not applicable
No tool was picked for this intent.
arguments
{}
model: gemini-2.5-flash

Add the tools this site is missing

Our scanner reads your website and suggests the right WebMCP tools for it.
Reads the site's public pages; takes a few seconds.
The open source webmcp plugin teaches your coding agent to audit a site, implement tools on document.modelContext, and verify them in a real browser. npx @ora-ai/webmcp-verify runs the verification on its own. No signup, no hosted service.

how this was captured

observed via
capture shim (Chromium 151.0.7922.34)
chrome
151.0.7922.34
capture shim
v3
spec snapshot
2026-11-10
mode
fast
pages
1 - entry page only
tools
2
invoked
not invoked; a live audit calls them
run time
11s
finished
Nov 18, 2026
Checked the way in-browser agents discover tools: the top-level document's modelContext registry, read after the page settles.